Another Test for Lightning Protection

Jeffrey R. Jowett, MeggerFall 2019 Columns, In Every Issue, Tech Tips

It doesn’t take an electrician or engineer to know that lightning is a major cause of electrical interference and damage. Protecting the electrical system against such a danger is paramount. A lightning stroke can be hotter than the surface of the sun, with voltage estimated as high as 120 million volts, including 400 kA and 500 megajoules of energy. Utility …

Electrical Service Work and Worker Fatigue: Take Care of Yourself!

Ron Widup, Shermco IndustriesFall 2019 Columns, In Every Issue, Safety Corner

Chances are you are in an electrical career you love: Testing, maintaining, installing, commissioning, designing, rebuilding, engineering, improving…and generally making electrical power systems safer and better. But are you doing so with a focus on managing the possible onset of acute or chronic fatigue? We live in a busy world — do more with less; be efficient in your tasks; …

NFPA 70E — 2021 Edition: Second Draft Meeting Highlights and Summary

Ron Widup and James (Jim) R. WhiteFall 2019 Columns, In Every Issue, NFPA 70E and NETA

The second draft technical committee meeting for the 2021 Edition of NFPA 70E was held July 15–19, 2019 in Indianapolis, Indiana. The public comments submitted for committee action following the first draft meeting were discussed and voted on. NETA was represented at the meeting and participated in the actions. To remind everyone of the NFPA process for changes to a …

NETA World Keeps You One Step Ahead of Emerging Technology

Scott Blizard, American Electrical Testing Company LLCFall 2019 Columns, In Every Issue, President's Desk

Emerging technologies continually alter the way electrical testing is performed in the field. New technology can vary from more efficient ways to perform long-standing test routines to introducing a new test technology and just about everything in between. This issue’s authors share their knowledge of recent developments in the field of electrical testing. Fall is typically one of the busiest …

How Multi-Function Numerical Protection Relays Use Symmetrical Components

Steve Turner, Arizona Public Service CompanyIn Every Issue, Relay Column, Summer 2019 Columns

Multi-function protection relays calculate and use symmetrical components to enhance their performance during system faults. This can be illustrated in two specific examples: (1) zero-sequence current elimination for transformer differential protection and (2) negative-sequence current detection to inhibit out-of-step blocking. Zigzag Transformer Inside Transformer Differential Zone A shunt-connected zigzag transformer provides a zero-sequence current sink for ungrounded systems such as …

Arc Rated Clothing and Electrical Hazard Footwear

Paul Chamberlain, Asplundh Engineering Services, LLCIn Every Issue, Safety Corner, Summer 2019 Columns

Everyone wears clothes, at least when out in public. However, not everyone needs to wear clothes specially designed and tested to protect them from hazards they could find in their workplace. If your employees work on or near electric power, generation, transmission, and distribution equipment, specialized clothing is necessary for certain tasks.  OSHA 29 CFR 1910.269 states that employers must …

Using NFPA 70E to Stay Alive

James R. White, Shermco IndustriesIn Every Issue, Summer 2019 Columns, Tech Quiz

This month’s Tech Quiz takes a bit different look at NFPA 70E requirements. What is involved in electrical testing? As with most things, it’s not as simple as it may seem. 1. If you are a crew leader, what is the first thing you would do to test a transformer? a. De-energize it b. Isolate it by lockout/tagout (LOTO) c. …

10 Design Features for Electrical Safety

Jeffrey R. Jowett, MeggerIn Every Issue, Summer 2019 Columns, Tech Tips

The National Fire Protection Association (NFPA®) revised its NFPA 70E, Standard for Electrical Safety in the Workplace in 2018 “to assist OSHA in preparing an electrical safety standard that would serve OSHA’s needs and that could be expeditiously promulgated through the provisions of…the Occupational Safety and Health Act.” Responsible electrical test instrumentation manufacturers accept 70E as a valuable guideline as …

A Guide to NFPA 70E

Ron Widup and James (Jim) R. WhiteIn Every Issue, NFPA 70E and NETA, Summer 2019 Columns

Many companies and people rely on NFPA 70E to guide them as they develop and implement electrical safe work practices. They look at a line or possibly a paragraph or two and believe they have the gist of the issue. Maybe, but they often misinterpret what they read or implement it incorrectly. Unfortunately, there’s a plethora of misleading or incorrect …